DT-10000VA 110V - 220V voltaj dönüştürücü

DT/ST Serisi toroidal yükseltici/alçaltıcı transformatör (100VA-10KVA) düşük EMI, kompakt tasarım ve konut, ticari ve endüstriyel kullanım için güvenilir performans ile 110V-220V AC'yi verimli bir şekilde dönüştürür.

  • Güç: 500VA-10000VA
  • Giriş Voltajı: 110-120VAC 220-240VAC (Diğer Voltajlar Özelleştirme Mevcuttur)
  • Çıkış Gerilimi: 220-240VAC 110-120VAC (Diğer Voltajlar Özelleştirilebilir)
  • Aşama Sayısı: 1
Şurada paylaş:

Açıklama

DT-10000VA step up down transformer

  • Output socket on the enclosure
  • No carrying handle at this rating — the frame is intended for fixed mounting
  • Input voltage selection by rotary switch
  • AÇMA/KAPAMA düğmesi
  • Fuse and MCB protection
  • Warranty: twelve months from delivery

Fonksiyonlar

  • Supplies a whole panel or machine cell from a supply of the opposite voltage class.
  • Input tap selected for the local grid, keeping the secondary close to nominal.
  • Selector positions 110V, 120V, 220V and 240V; bespoke ratios available.
  • Secondary available at 110/120V or 220/240V depending on the direction.
  • Used for CNC cells, laundry rooms, commercial kitchens and small production floors.

JOHSUN GROUP_页面_054

Model Kapasite Paket Boyutu (cm) Adet/Paket
ST/DT-100 100w 41.5×27×38 12 ADET
ST/DT-200 200W 41.5×27×38 12 ADET
ST/DT-300 300W 48×29×41 12 ADET
ST/DT-500 500W 48×29×41 12 ADET
ST/DT-750 750W 48×29×41 12 ADET
ST/DT-1000 1000W 49.5×33×21 2 ADET
ST/DT-1500 1500W 49.5×33×21 2 ADET
ST/DT-2000 2000W 49.5×33×21 2 ADET
ST/DT-3000 3000W 54.5×33×24.5 2 ADET
ST/DT-4000 4000W 54.5×33×24.5 2 ADET
ST/DT-5000 5000W 54.5×33×24.5 2 ADET
ST/DT-7500 7500W 42.5×33×28 1 ADET
ST/DT-10000 1000oW 42.5×33×28 1 ADET

Teknik Özellikler

Güç: 10,000VA, single phase, 50/60Hz

Giriş gerilimi: 110–120VAC / 220–240VAC; other voltages customisation available

Output voltage: 220–240VAC / 110–120VAC; other voltages customisation available

Phases: one

Type: step up & down transformer / voltage converter

Input connection: terminal block for fixed wiring, or plug

Socket on the body: yes

Verimlilik: 80%

Power supply frequency: 50/60Hz

Operating temperature range: 0°C to +40°C

Protection: MCB and fuse, circuit breaker

OEM/ODM: accept with MOQ

Spare parts: discussion

Warranty: 12 months

■ How to Choose This Transformer

Ten kilovolt-amperes is distribution-scale, so size for the expected simultaneous load rather than the sum of everything installed. Diversity in a real workshop or laundry is rarely 100 %, but the heaviest motor still sets the ceiling: on this frame allow about 5,200W of resistive load, 3,200W of fan and pump duty, or 1,600W of compressor load. We normally recommend planning so that the usual operating load sits at around 70 % of the rating.

Three items to settle before ordering:

  • whether the secondary will feed a sub-board or a single machine, which determines conductor and breaker sizing;
  • the conversion direction together with the socket standard for your market;
  • the mounting position and the clearance available for convection cooling.

■ System Design Around a 10KVA Frame

At 110V and 5,200W the secondary current approaches 47A, which calls for a cable cross-section far larger than an equivalent 220V circuit — under-sizing the secondary cable is the most common installation error we see on 10KVA projects. The unit ships one to a carton at 42.5 × 33 × 28cm and is normally wall-bracketed or set on a plinth; it is heavy enough to need two people. Each unit is dielectric-tested and then run at rated load, with output voltage, no-load current and winding resistance recorded against the serial number for twelve months.

Where the connected load genuinely exceeds the figures above, two 10KVA frames on separate circuits are often more economical than moving to a non-standard rating. Discuss the duty cycle with us before assuming a bespoke build is required.

The unit is heavy enough to need two people when positioning it on a bracket or plinth. Wooden-crate packing is available for export shipments where the standard carton is not considered sufficient.

■ Pricing, Ordering & Quality Assurance

Step Up & Step Down Transformer Price Range (100VA–10KVA)

Pricing for the DT/ST series depends on capacity, the input/output voltage combination you need, socket type, and whether a voltage selector or MCB protection is fitted. The table below gives indicative FOB levels so you can budget before requesting a firm quotation.

Model Kapasite Input / Output Voltage Tipik Uygulama Indicative FOB Price (per pc)*
ST/DT-100 100 VA 110V ↔ 220V selectable Small electronics, chargers, control circuits US$ 10–15
ST/DT-200 200 VA 110V ↔ 220V selectable Bench instruments, small appliances US$ 11–16
ST/DT-300 300 VA 110V ↔ 220V selectable Audio equipment, laboratory benches US$ 12-18
ST/DT-500 500VA 110V ↔ 220V selectable Refrigeration units, printers, POS systems US$ 12-20
ST/DT-1000 1000VA 110V ↔ 220V selectable Power tools, kitchen equipment, single machines US$ 21-30
ST/DT-1500 1500VA 110V ↔ 220V selectable Motor-driven machines, imported appliances US$ 23-35
ST/DT-2000 2000VA 110V ↔ 220V selectable Compressors, welders, multi-outlet benches US$ 25-37
ST/DT-3000 3000VA 110V ↔ 220V selectable Small production lines, test rigs US$ 33-43
ST/DT-5000 5000VA 110V ↔ 220V selectable HVAC, industrial machinery US$ 52-62
ST/DT-7500 7500 VA 110V ↔ 220V selectable Heavy workshop loads US$ 75-87
ST/DT-10000 10000VA 110V ↔ 220V selectable CNC equipment, whole-panel supply US$ 85-112

* Indicative FOB Ningbo/Shanghai, standard configuration, based on 50 pcs per size. Not a formal offer — final price depends on your voltage combination, socket standard, enclosure and order quantity.

  1. The efficiency of the DT/ST series is 80%. For equipment with motors or compressors, the starting current will multiply — always reserve adequate power margin.
  2. Pure resistive / electronic loads: choose a transformer with capacity ≥ 1.5× the equipment rated power.
  3. Inductive loads such as motors and compressors: choose a transformer with capacity ≥ 2.5–3× the equipment rated power.
  4. This table is for reference only. Confirm the final solution according to the rated power and duty cycle shown on your equipment nameplate.

MOQ, Lead Time & Ordering Information

Minimum Order Quantity (MOQ) 1 PC for standard DT models. Smaller trial orders can be discussed for first-time buyers.
Custom / OEM orders 50 PCS for custom voltage, custom socket layout, branded front panel or non-standard capacity.
Sample 1-2 pcs sample available for verified buyers. Sample lead time 3-5 working days.
Teslim süresi 10-20 working days for standard models after order confirmation and deposit; 15-25 working days for OEM or custom configurations.
Paketleme Export carton with foam. 1/2/6 pcs per carton – see the packing table above.
Payment terms 100% TT IN ADVANCE FOR RETAIL/SAMPLE; 30% TT IN ADVANCE AS DEPOSIT, THE BALANCE BEFORE SHIPMENT.
Shipping FOB Ningbo. CIF and door-to-door available on request.
Garanti 12 MONTHS FROM DELIVERY DATE

Certifications & Quality Assurance

DT/ST series step up and step down transformers are produced under our ISO 9001 quality management system, and every unit is 100% function-tested before packing.

CE Certified  |  RoHS Compliant  |  IEC Tested  |  ISO 9001  |  EMC Tested  |  12-Month Warranty

Certificates and routine test reports can be issued as PDF on request, for customs clearance, tender submissions or distributor onboarding.

■ FAQ

What is the Johsun DT 10000VA designed for?

The Johsun DT 10000VA is the top of the DT range and the only model supplied one unit to a carton. It is built for distribution-scale duty: a single unit feeding a sub-board, a CNC cell, a commercial laundry or a small production floor that runs entirely on equipment of the opposite voltage class. Where two smaller frames would be needed on separate circuits, one Johsun DT 10000VA usually works out cheaper to install.

Can a 10kVA step up transformer feed a whole sub-board?

Yes, and that is its normal role. A 10kVA step up transformer supplies approximately 5,200W of resistive load, 3,200W of fan and pump duty or 1,600W of compressor load, which is enough for a small distribution board once diversity is taken into account. Work from the expected simultaneous load rather than the sum of everything installed, and plan so the usual operating load sits at around 70% of the rating.

Is a 10000 watts step down power transformer 220V to 110V available with a custom socket?

Yes. A 10000 watts step down power transformer 220V to 110V can be supplied with a market-specific socket, a fixed ratio instead of a selector, a resettable breaker, or a branded front panel. Because the frame is normally hardwired rather than plugged in, most buyers specify the terminal arrangement instead of a socket, and we will confirm the terminal layout against your panel drawing.

What cable size does the secondary need?

At 110V and 5,200W the secondary current approaches 47A, which requires a far larger conductor cross-section than an equivalent 220V circuit. Under-sizing the secondary cable is the most common installation error we see on 10KVA projects, so size the cable for the current over the full run length and protect it with its own breaker rather than relying on the primary device.

How is a 10KVA unit packed and delivered?

One unit per carton at 42.5 × 33 × 28cm. The frame is heavy enough to need two people when it is positioned on a wall bracket or floor plinth, and wooden-crate packing is available for export shipments where the carton alone is not considered sufficient. Standard lead time is 10–20 working days, extending to 15–25 working days for custom voltages or branded panels.

Teklif İste

Teknik özelliklerinizi, miktarınızı veya kullanım alanınızı bize bildirin; size özel bir teklifle geri dönüş yapalım.