En İyi Seyahat Voltaj Dönüştürücü STU Serisi 100VA-3000VA

Fabrikadan en iyi seyahat voltaj dönüştürücüsü: STU Serisi 100VA–3000VA. OEM/ODM, özel tasarım, düşük minimum sipariş miktarı (MOQ), endüstriyel, ticari ve dağıtım alıcıları için toptan fiyat.

Şurada paylaş:

Açıklama

STU series travel voltage converter 100VA–3000VA

  • Sockets optional, single or double
  • Carrying handle on all frames up to this rating
  • Input voltage selector
  • AÇMA/KAPAMA düğmesi
  • Fuse and MCB protection
  • Warranty: twelve months from delivery

Fonksiyonlar

  • Automatic, bidirectional conversion between 110–120V and 220–240V supplies.
  • Input tap matched to the local grid so output stays close to the rated figure.
  • Selector covers 110V, 120V, 220V and 240V; custom voltages available.
  • Output through the on-board socket, with a USB outlet rated 5A.
  • Intended for control panels, HVAC controls, lighting circuits, test benches and light industrial machinery.
Model Kapasite Paket Boyutu (cm) Adet/Paket
STU-100 100W 41.5×27×38 12 ADET
STU-200 200W 41.5×27×38 12 ADET
STU-300 300W 48×29×41 12 ADET
STU-500 500W 48×29×41 12 ADET
STU-750 750W 48×29×41 12 ADET
STU-1000 1000W 49.5×33×21 2 ADET
STU-1500 1500W 49.5×33×21 2 ADET
STU-2000 2000W 49.5×33×21 2 ADET
STU-3000 3000W 54.5×33×24.5 2 ADET
STU-4000 4000w 54.5×33×24.5 2 ADET
STU-5000 5000W 54.5×33×24.5 2 ADET
STU-7500 7500W 42.5×33×28 1 ADET
STU-10000 10000W 42.5×33×28 1 ADET

STU serisi seyahat voltaj dönüştürücüsü, farklı bölgelerde kullanılan ekipmanlar için güvenli ve güvenilir voltaj dönüştürme gerektiren endüstriyel ve ticari ortamlar için tasarlanmış, ağır hizmet tipi bir AC transformatördür. 100VA ile 3000VA arasında değişen kapasiteler sunan STU serisi, çok çeşitli giriş/çıkış gerilim kombinasyonlarını destekler; bu özelliği sayesinde endüstriyel kullanıcılar, ticari tesisler, elektrik müteahhitleri ve elektrik dağıtım şebekeleri için ideal bir çözümdür.

Bu dönüştürücüler, sıkı güvenlik ve verimlilik standartlarını korurken yerel şebeke gerilimlerinde çalışması gereken kontrol panelleri, HVAC sistemleri, aydınlatma kontrol sistemleri, test ekipmanları ve küçük endüstriyel makinelere güç sağlamak için yaygın olarak kullanılmaktadır. Sağlam çekirdekler, yüksek kaliteli sargılar ve aşırı yük koruması ile üretilen STU serisi, 7/24 çalışan uygulamalarda istikrarlı çıkış, düşük gürültü ve uzun vadeli güvenilirlik sağlar.

JOHsunTECH, üretici, fabrika ve OEM/ODM çözüm sağlayıcısı olarak STU serisindeki en iyi seyahat voltaj dönüştürücüsünü sunmaktadır. Dağıtıcılarımıza ve toptan satış ortaklarımıza, düşük minimum sipariş miktarı (MOQ), esnek konfigürasyon seçenekleri ve bölgesel ve marka gereksinimlerinizi karşılayacak özel etiketleme veya tasarım seçenekleri sunuyoruz; tüm bunları rekabetçi toptan satış fiyatlarıyla gerçekleştiriyoruz.

■ How to Choose This Transformer

This configuration is specified by buyers who need a converter that survives continuous commercial use rather than occasional travel, so the deciding factor is duty cycle rather than peak wattage. For 24/7 duty we recommend operating at no more than 70 % of the nameplate figure — about 2,100W on a 3000VA frame — which leaves headroom for the ambient rise inside a panel or cabinet. If the unit will be installed in an enclosure rather than in free air, derate further and add forced ventilation.

Three points to confirm before ordering:

  • the continuous and peak load, and how many hours a day the unit will run;
  • the socket standard for your market and whether one or two sockets are required;
  • whether the unit will sit in free air or inside a control cabinet.

■ Applications in Practice

Control panels, HVAC control circuits, lighting controls, test benches and small industrial machinery that has to operate on a mains voltage different from the building supply. The common thread is that the equipment runs for hours at a time, so an under-built converter would overheat. Because these units are passive, they inject no high-frequency switching noise into a panel and do not need an EMC filter to coexist with analogue signal wiring.

■ Pricing, Ordering & Quality Assurance

Step Up & Step Down Transformer Price Range (100VA–10KVA)

Pricing for the DT/ST series depends on capacity, the input/output voltage combination you need, socket type, and whether a voltage selector or MCB protection is fitted. The table below gives indicative FOB levels so you can budget before requesting a firm quotation.

Model Kapasite Input / Output Voltage Tipik Uygulama Indicative FOB Price (per pc)*
ST/DT-100 100 VA 110V ↔ 220V selectable Small electronics, chargers, control circuits US$ 10–15
ST/DT-200 200 VA 110V ↔ 220V selectable Bench instruments, small appliances US$ 11–16
ST/DT-300 300 VA 110V ↔ 220V selectable Audio equipment, laboratory benches US$ 12-18
ST/DT-500 500VA 110V ↔ 220V selectable Refrigeration units, printers, POS systems US$ 12-20
ST/DT-1000 1000VA 110V ↔ 220V selectable Power tools, kitchen equipment, single machines US$ 21-30
ST/DT-1500 1500VA 110V ↔ 220V selectable Motor-driven machines, imported appliances US$ 23-35
ST/DT-2000 2000VA 110V ↔ 220V selectable Compressors, welders, multi-outlet benches US$ 25-37
ST/DT-3000 3000VA 110V ↔ 220V selectable Small production lines, test rigs US$ 33-43
ST/DT-5000 5000VA 110V ↔ 220V selectable HVAC, industrial machinery US$ 52-62
ST/DT-7500 7500 VA 110V ↔ 220V selectable Heavy workshop loads US$ 75-87
ST/DT-10000 10000VA 110V ↔ 220V selectable CNC equipment, whole-panel supply US$ 85-112

* Indicative FOB Ningbo/Shanghai, standard configuration, based on 50 pcs per size. Not a formal offer — final price depends on your voltage combination, socket standard, enclosure and order quantity.

  1. The efficiency of the DT/ST series is 80%. For equipment with motors or compressors, the starting current will multiply — always reserve adequate power margin.
  2. Pure resistive / electronic loads: choose a transformer with capacity ≥ 1.5× the equipment rated power.
  3. Inductive loads such as motors and compressors: choose a transformer with capacity ≥ 2.5–3× the equipment rated power.
  4. This table is for reference only. Confirm the final solution according to the rated power and duty cycle shown on your equipment nameplate.

MOQ, Lead Time & Ordering Information

Minimum Order Quantity (MOQ) 1 PC for standard DT models. Smaller trial orders can be discussed for first-time buyers.
Custom / OEM orders 50 PCS for custom voltage, custom socket layout, branded front panel or non-standard capacity.
Sample 1-2 pcs sample available for verified buyers. Sample lead time 3-5 working days.
Teslim süresi 10-20 working days for standard models after order confirmation and deposit; 15-25 working days for OEM or custom configurations.
Paketleme Export carton with foam. 1/2/6 pcs per carton – see the packing table above.
Payment terms 100% TT IN ADVANCE FOR RETAIL/SAMPLE; 30% TT IN ADVANCE AS DEPOSIT, THE BALANCE BEFORE SHIPMENT.
Shipping FOB Ningbo. CIF and door-to-door available on request.
Garanti 12 MONTHS FROM DELIVERY DATE

Certifications & Quality Assurance

DT/ST series step up and step down transformers are produced under our ISO 9001 quality management system, and every unit is 100% function-tested before packing.

CE Certified  |  RoHS Compliant  |  IEC Tested  |  ISO 9001  |  EMC Tested  |  12-Month Warranty

Certificates and routine test reports can be issued as PDF on request, for customs clearance, tender submissions or distributor onboarding.

■ FAQ

How long can this converter run continuously?

Indefinitely within rating. For continuous duty we recommend loading to no more than 70 % of the nameplate figure so the winding stays cool and service life is not shortened.

Is the output isolated from the input?

Yes. The STU range uses a double-wound core, so primary and secondary are galvanically separated rather than sharing a winding.

Does it need any maintenance?

Very little. Keep the ventilation slots clear of dust, check the fuse annually and re-torque the terminals at the two-year service interval. There are no fans, capacitors or firmware to service.

Can it be supplied with a custom voltage ratio?

Yes, both windings can be wound to a non-standard ratio. Production lead time for custom configurations is 15–25 working days against a minimum of fifty pieces.

Teklif İste

Teknik özelliklerinizi, miktarınızı veya kullanım alanınızı bize bildirin; size özel bir teklifle geri dönüş yapalım.

+86-15658763197 Telefon sales@johsuntech.com E-posta WhatsApp'ta sohbet edin WhatsApp