TC-1000

TC/THG Series toroidal step-up/step-down transformer (100VA–10KVA) efficiently converts 110–220V AC with low EMI, compact design, and stable output, ideal for residential, commercial, and industrial applications.

Share to:

Description

TC-1000 toroidal step up and down transformer 1000VA

■ TC-1000 Toroidal Transformer

The TC-1000 is the one-kilowatt model of the TC/THG toroidal family: a compact, low-noise step-up and step-down transformer in a double-core toroidal build. It is the size most buyers choose for kitchen equipment, power tools and audio systems where a laminated-core unit would buzz or take up too much space.

■ Unit Specification

Model TC-1000 (THG-1000 equivalent)
Capacity 1000VA
Conversion 110–220VAC ⇄ 220–110VAC
Phases / frequency Single · 50/60Hz
Efficiency 80%
Core Double power core, toroidal winding
Sockets One or two, model dependent
Protection Fuse
Switch ON/OFF
Input voltage selector Available as an option
Carton 32 × 17.5 × 26.5cm, 6 pcs per carton
Warranty 12 months

■ Load Guidance

At 1000VA and 80% efficiency the TC-1000 will carry about 800W of continuous resistive load, or roughly 300–400W of motor load once starting current is allowed for. Practical pairings we see most often:

  • Microwave or coffee machine — one at a time, check the rating plate
  • Refrigerator under 200W running load — acceptable
  • Power drill or router up to 300W — acceptable
  • Audio system or amplifier — excellent match, very low hum
  • Any air-conditioning load — not recommended at this rating

Where more headroom is needed, step up to the TC/THG 100VA–10KVA toroidal range which reaches 10KVA on the same platform.

■ Why the Toroidal Build Matters Here

At one kilowatt a conventional laminated transformer produces an audible 50/60Hz hum that is noticeable in a quiet room. The toroidal core in the TC-1000 reduces that substantially, and the double-core winding also cuts stray flux — important if the unit sits near a turntable, a sensor or measurement wiring.

■ Ordering

Standard units ship in 10–20 working days from deposit. Custom voltage ratios, alternative socket types, two-socket layouts and branded panels are produced to order with a minimum order quantity of 50 pieces. Fuse, socket standard and input voltage should be specified on the enquiry.

■ What Makes the TC-1000 Different from a Laminated 1KVA

Compare the TC-1000 with a conventional laminated 1000VA converter and the differences are audible and measurable. The toroidal core reduces core loss, cuts audible hum to a level that is unobtrusive in a quiet room and confines the magnetic field inside the winding. For a kitchen appliance or an audio system, that combination is worth the small premium.

■ Typical Installations

  1. Radio and hi-fi equipment imported from a 110V market and used on 220V mains.
  2. Small catering equipment — coffee grinders, mixers, food processors — used on a foreign supply.
  3. Power tools rated for 110V operated from a 220–240V site supply.
  4. Laboratory and calibration benches where a noisy converter would disturb measurements.

■ Handling and Siting

Allow 5cm of free air around the case. The toroidal transformer should sit on a flat, firm surface; if it is bolted down, tighten the mounting bolt firmly but do not over-compress the rubber pad, as excessive pressure can distort the core and increase no-load current. The unit can be left permanently energised, but switch it off when not in use if the appliances have no standby requirement.

■ Ordering Details

Standard supply Single or two output sockets; fuse protection; ON/OFF switch
Options Input voltage selector, custom output voltage, branded panel
Carton 32 × 17.5 × 26.5cm, six units per carton
MOQ 1 pc standard · 50 pcs for custom configuration
Lead time 10–20 working days standard · 15–25 working days custom
Warranty 12 months from delivery date

■ Step Up & Step Down Transformer Price Range (100VA–10KVA)

Pricing for the DT/ST series depends on capacity, the input/output voltage combination you need, socket type, and whether a voltage selector or MCB protection is fitted. The table below gives indicative FOB levels so you can budget before requesting a firm quotation.

Model Capacity Input / Output Voltage Typical Application Indicative FOB Price (per pc)*
ST/DT-100 100VA 110V ↔ 220V selectable Small electronics, chargers, control circuits US$ 10–15
ST/DT-200 200VA 110V ↔ 220V selectable Bench instruments, small appliances US$ 11–16
ST/DT-300 300VA 110V ↔ 220V selectable Audio equipment, laboratory benches US$ 12-18
ST/DT-500 500VA 110V ↔ 220V selectable Refrigeration units, printers, POS systems US$ 12-20
ST/DT-1000 1000VA 110V ↔ 220V selectable Power tools, kitchen equipment, single machines US$ 21-30
ST/DT-1500 1500VA 110V ↔ 220V selectable Motor-driven machines, imported appliances US$ 23-35
ST/DT-2000 2000VA 110V ↔ 220V selectable Compressors, welders, multi-outlet benches US$ 25-37
ST/DT-3000 3000VA 110V ↔ 220V selectable Small production lines, test rigs US$ 33-43
ST/DT-5000 5000VA 110V ↔ 220V selectable HVAC, industrial machinery US$ 52-62
ST/DT-7500 7500VA 110V ↔ 220V selectable Heavy workshop loads US$ 75-87
ST/DT-10000 10000VA 110V ↔ 220V selectable CNC equipment, whole-panel supply US$ 85-112

* Indicative FOB Ningbo/Shanghai, standard configuration, based on 50 pcs per size. Not a formal offer — final price depends on your voltage combination, socket standard, enclosure and order quantity.

  1. The efficiency of the DT/ST series is 80%. For equipment with motors or compressors, the starting current will multiply — always reserve adequate power margin.
  2. Pure resistive / electronic loads: choose a transformer with capacity ≥ 1.5× the equipment rated power.
  3. Inductive loads such as motors and compressors: choose a transformer with capacity ≥ 2.5–3× the equipment rated power.
  4. This table is for reference only. Confirm the final solution according to the rated power and duty cycle shown on your equipment nameplate.

■ MOQ, Lead Time & Ordering Information

Minimum Order Quantity (MOQ) 1 PC for standard DT models. Smaller trial orders can be discussed for first-time buyers.
Custom / OEM orders 50 PCS for custom voltage, custom socket layout, branded front panel or non-standard capacity.
Sample 1-2 pcs sample available for verified buyers. Sample lead time 3-5 working days.
Lead time 10-20 working days for standard models after order confirmation and deposit; 15-25 working days for OEM or custom configurations.
Packing Export carton with foam. 1/2/6 pcs per carton – see the packing table above.
Payment terms 100% TT IN ADVANCE FOR RETAIL/SAMPLE; 30% TT IN ADVANCE AS DEPOSIT, THE BALANCE BEFORE SHIPMENT.
Shipping FOB Ningbo. CIF and door-to-door available on request.
Warranty 12 MONTHS FROM DELIVERY DATE

■ Certifications & Quality Assurance

DT/ST series step up and step down transformers are produced under our ISO 9001 quality management system, and every unit is 100% function-tested before packing.

CE Certified  |  RoHS Compliant  |  IEC Tested  |  ISO 9001  |  EMC Tested  |  12-Month Warranty

Certificates and routine test reports can be issued as PDF on request, for customs clearance, tender submissions or distributor onboarding.

Request Quote

Tell us your specifications, quantity, or application scenario and we will reply with a tailored quote.

+86-15658763197 Phone sales@johsuntech.com E-mail Chat on WhatsApp WhatsApp